FOR STABILIZATION OF PELVIC FRACTURES WITH THE CORRECT FORCE
The SAM® Pelvic Sling II™ was designed not to over-tighten or under-tighten, unlike other commercial binders which allow unlimited force to be applied to the patient.
SAM® Pelvic Sling is de
FOR STABILIZATION OF PELVIC FRACTURES WITH THE CORRECT FORCE
The SAM® Pelvic Sling II™ was designed not to over-tighten or under-tighten, unlike other commercial binders which allow unlimited force to be applied to the patient. Researchers at Legacy Health System utilized cadaver studies and clinical trials to determine the optimum range of force required to safely and effectively close an unstable pelvic fracture.
The SAM® Pelvic Sling II's™ patented auto-stop buckle will not allow a compression force greater than 33lbs. This is vital in high stress environments where over-tightening by emergency medical personnel under duress could potentially be extreme and harmful.
Trauma surgeons around the world recognize the importance of stabilizing pelvic fractures during the critical first "golden hour" following severe trauma. Because of the potentially devastating hemorrhage associated with such fractures, standard first aid protocol includes applying some type of circumferential binder around the victim's hips.
NEWLY IMPROVED ONE PIECE DESIGN
The SAM® Pelvic Sling II™ improves upon our groundbreaking original pelvic sling. It is still the only force-controlled circumferential pelvic belt scientifically proven in peer-reviewed studies to safely and effectively reduce and stabilize open-book pelvic ring fractures.
The SAM® Pelvic Sling II™ is an improved, simpler design with no detachable hardware. It is more compact, easy to use (only three steps), quick to apply (usually in less than one minute), and is sized to fit (without cutting or trimming) 98% of the adult population. It does not require a fine touch to operate and gives clear feedback by sound and feel to confirm correct application.
The sling is durable i.e. not affected by extremes of moisture, temperature, or by exposure to hard or sharp objects. It is also radiolucent, MRI safe, and cleans for re-use with common detergents or anti-microbial solutions.
IMPORTANT WARNING
Based on in vitro testing, the SAM® Pelvic Sling II™ will not present a hazard or risk to a patient undergoing an MRI procedure using an MR system operating at 3-Tesla or less. The SAM® Pelvic Sling II™ contains ferromagnetic springs in the buckle. Therefore, it is important to ensure that the SAM Pelvic Sling II is firmly applied to the patient prior to entry into the MRI environment (as stated in the labeling for this device). Accordingly, there will be no hazard or risk to a patient undergoing an MRI procedure. The SAM® Pelvic Sling II™ should not be removed from the patient while in the MRI system room.
WHY DOES CONTROLLING CIRCUMFERENTIAL FORCE MATTER IN THE TREATMENT OF PELVIC FRACTURES?
At the time of initial evaluation, the exact type of fracture is usually unknown. In some cases, too little force will not close or stabilize the the fracture; in others, too much force can collapse the pelvic ring. The SAM® Pelvic Sling II™ stands alone as the only pelvic binder pre-programmed to apply the safe and correct force for all pelvic fractures.
BENEFITS AND FEATURES
|
ISO 13485:2003
NSN# 6516-01-509-6866
Meets ASTM Standard F2428-04
PATENTED
Made in USA
CE Approved